Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 285: 121918, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36179569

RESUMO

An easy and reliable method is optimized for extractive spectrophotometric assessment of platinum(IV) with 4-(4'-nitrobenzylideneimino)-3-methyl-5-mercapto-1,2,4-triazole as an extractant. The basis of this method is the formation of red platinum(IV) complex with the above reagent in acetate buffer medium (pH 5.0) and extraction in chloroform. Good linearity with regression equation as y = 1.011 × 104 ×  + 0.002 having correlation coefficient (R2) of 0.998 over concentration up to 17.5 µg mL-1 of platinum(IV) was achieved with apparent molar absorptivity of 1.011 × 104 L mol-1 cm-1. The limit of detection (0.22 µg mL-1), limit of quantification (0.73 µg mL-1) and Sandell's sensitivity (0.0193 µg cm-2) were also estimated. The interference of various cations was removed by using proper masking agents and consequently by using EDTA and citrate to mask certain transition metals, the method becomes highly specific for platinum(IV), including the effects of platinum group metals. The method is effectively used for determination of platinum(IV) from environmental and real samples such as alloys, catalysts, thermocouple wire and pharmaceutical sample.


Assuntos
Cisplatino , Platina , Espectrofotometria/métodos , Ligas , Indicadores e Reagentes
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 189: 443-453, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28843878

RESUMO

The aim of the present work is to develop an efficient, simple and selective moreover cost-effective method for the extractive spectrophotometric determination of copper(II) by using the Schiff base 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole [CBIMMT]. This chromogenic reagent forms a yellow coloured complex with copper(II) in acetate buffer at pH4.2. The copper(II) complex with ligand is instantly extracted into chloroform and shows a maximum absorbance at 414nm which remains stable for >48h. The composition of extracted complex is found to be 1:2 [copper(II): reagent] which was ascertained using Job's method of continuous variation, mole ratio method and slope ratio method. Under optimal conditions, the copper(II) complex in chloroform adheres to Beer's law up to 17.5µgmL-1 of copper(II). The optimum concentration range obtained from Ringbom's plot is from 5µgmL-1 to 17.5µgmL-1. The molar absorptivity, Sandell's sensitivity and enrichment factor of the extracted copper(II) chelate are 0.33813×104Lmol-1cm-1, 0.01996µgcm-2 and 2.49 respectively. In the extraction of copper(II), several affecting factors including the solution pH, ligand concentration, equilibrium time, effect of foreign ions are optimized. The interfering effects of various cations and anions were also studied and use of masking agents enhances the selectivity of the method. The chromogenic sulphur containing reagent, 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole has been synthesized in a single step with high purity and yield. The synthesized reagent has been successfully applied first time for determination of copper(II). The reagent forms stable chelate with copper(II) in buffer medium instantly and quantitatively extracted in chloroform within a minute. The method is successfully applied for the determination of copper(II) in various synthetic mixtures, complexes, fertilizers, environmental samples such as food samples, leafy vegetables, and water samples. The results are compared with those obtained with a reference procedure. Good agreement was attained. All the obtained results are indicative of a convenient, fast method for the extraction and quantification of micro levels of copper(II) from various environmental matrices without use of sophisticated instrumentation and procedure. The method showed a relative standard deviation of 0.42%.


Assuntos
Cobre/análise , Análise Custo-Benefício , Meio Ambiente , Fertilizantes/análise , Análise de Alimentos/economia , Extração Líquido-Líquido/métodos , Triazóis/química , Verduras/química , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Íons , Folhas de Planta/química , Reprodutibilidade dos Testes , Solventes/química , Espectrofotometria/métodos , Espectrofotometria Ultravioleta , Fatores de Tempo , Triazóis/síntese química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA